19–23 Jun 2023
Hofburg Palace & Online
Europe/Vienna timezone

Comparison of Xe-127 Measurements

P3.2-779
21 Jun 2023, 11:00
1h
Wintergarten

Wintergarten

Board: 31
E-poster T3.2 Radionuclide Technologies and Applications Lightning talks: P2.2, P3.2, P3.6

Speaker

Mr Troy Robinson (Idaho National Laboratory)

Description

Recent reports have shown that unusual xenon radionuclides can show up in grown based xenon detection systems that lead to false hits on all four of the regularly monitored radionuclides (Xe-135, Xe-133, Xe-133m, Xe-131m). Potential sources of these unusual radionuclides could be high flux neutron sources or spallation neutron sources that are operated in the vicinity of current ground based collection systems. The development of detection algorithms for these unusual xenon radionuclides is needed to prevent false positive detections from diverting analyst time and resources away from potential legitimate radionuclide detections. The Idaho National Laboratory Noble Gas Laboratory has developed the capability to produce Xe-127. This radionuclide has never been utilized in an interlaboratory comparison exercise. This work carries out a limited interlaboratory comparison exercise to demonstrate the potential for introducing Xe-127 and other unusual xenon radionuclides into future laboratory comparison exercises.

Promotional text

Comparison of independent laboratories measuring Xe-127.

E-mail [email protected]

Primary author

Mr Troy Robinson (Idaho National Laboratory)

Co-authors

Dr Matthew Goodwin (Atomic Weapons Establishment (AWE) Aldermaston) Matthew Watrous (Idaho National Laboratory)